FI-900

Features
・Flameproof enclosure (ATEX/IECEx/Japan Ex) that can even be used in H2 environment
・Comprehensive self-diagnostic function, and checks of gas concentrations as well as status using MODBUS communications
・Ideal for preventing explosions and monitoring concentrations of VOCs, and monitoring concentrations of hydrogen gas

Category:
Sampling method Suction type
Principle of detection Interferometer Method
Explosion protected construction Flameproof enclosures
Approvals Japan Ex, ATEX, IECEx
Power source 24 VDC±10 %
Dimensions Approx. 286 (W) x 453 (H) x 150 (D) mm
Weight Approx. 23kg
Operating temperature range -20 to +60 ℃ (no sudden changes)
Operating humidity range 0 to 95 %RH (no condensation/use of condensible gases within unit) (no condensation)
Target gas C2H4, C2H5OH, C2H6, C2HCL3, C3F8, C3H3N, C3H6, C3H6O, C3H8, C4H6, C5H8, C5H8O, C6H12, C6H12O2, C6H6, C7H14, C7H8, C8H10, C8H16, C8H8, CH2C2F4, CH2CL2, CH3CN, CH3OH, CH4, CO2, D2, DME, EtAc, H2, IPA, MEK, MIBK, MMA, n-C6H14, n-C7H16, NH3, nPAc, R-454C, SO2F2, VCM