GX-6000 for Benzene

・Up to 6 gases can be detected and displayed simultaneously.
・VOC can be detected by adoption of the PID sensor.
・Multi languages can be displayed (English and others).
・Measurement in a dark place is safely done with the LED light.
・Equipped with panic alarm & man down alarm function.
・Detect benzene selectively (Benzene select mode).

SKU: A0000P300L61 Category:
Sampling method Suction type
Principle of detection New Ceramic catalytic Method, Non-Dispersive Infrared Method, Potentiostatic Electrolysis Method, Membrane Type Galvanic Cell Method, Photo-Ionization Detector
Detection range Depend on target gas.
Type of alarm Gas alarm / fault alarm / panic alarm
man down alarm (option)
Display of alarm Blinking lamp / buzzer continuous modulated sound / gas concentration display and blinking alarm details / vibration
Explosion protected construction Intrinsic safety
Explosion-proof class IECEx : Ex ia IIC/IIB T4/T3 Ga
ATEX : II 1 G Ex ia IIC/IIB T4/T3 Ga
Ingress proof rating IP67
Approvals Japan Ex, ATEX, IECEx, Brazil Ex, JG
CE marking EMC / ATEX / RoHS
Power source Dedicated lithium ion battery unit or
Dedicated dry battery unit (AA alkaline dry battery 3 pcs.)
Continuous operation Approx. 14 hours (25 ºC, no alarm and no lighting) [litium ion battery unit]
Approx.8 hours (25 ºC, no alarm and no lighting) [dry battery unit]
Dimensions Approx. 70 (W) × 201 (H) × 54 (D) mm (projection portions excluded)
Weight Approx. 500 g [lithium ion battery unit] Approx. 450 g [dry battery unit]
Operating temperature range -20 to +50 ºC (no sudden changes)
Operating humidity range 0 to 95 %RH (no-condensing)
Target gas CH4, CL2, CO, CO2, H2S, HCN, i-C4H10, i-C4H8, NH3, NO2, O2, SO2
Target Gas

C4H10 (Isobutane), CH4 (Methane), CO (Carbon Monoxide), CO2 (Carbon Dioxide), H2S (Hydrogen Sulfide), NH3 (Ammonia), O2

Product Type

Portable

Industry

Automotive, Marine, Oil and Gas, Semiconductor

Lead Time

TBA