Sampling method | Suction type |
Principle of detection | New Ceramic catalytic Method |
Detection range | 0 to 10000 ppm (automatic range switching) Low : 0 to 1000 ppm High : 0 to 10000 ppm |
Alarm setpoints | 1st 250ppm / 2nd 500ppm |
Type of alarm | Gas alarm / fault alarm |
Display of alarm | Intermittent buzzer sound / blinking alarm lamp (red) and blinking gas / concentration display |
Explosion protected construction | Intrinsic safety |
Explosion-proof class | IECEx : Ex ia IIC T4 Ga ATEX : II1G Ex ia IIC T4 Ga |
Ingress proof rating | IP67 |
Approvals | Japan Ex, ATEX, IECEx, Brazil Ex |
CE marking | EMC / ATEX / RoHS |
Power source | AA alkaline battery x 4 |
Continuous operation | Approx. 15hours (new dry batteries, without alarms or lighting, at 25ºC) (CH4 spec.) Approx. 20hours (new dry batteries, without alarms or lighting, at 25ºC) (HC spec.) |
Dimensions | Approx. 80 (W) x 124 (H) x 36 (D) mm (excluding projections) |
Weight | Approx. 260 g (without batteries) |
Operating temperature range | -20 to +50 ºC (no sudden changes) |
Operating humidity range | 0 to 95 %RH (no condensation) |
Target gas | C2H2, C2H4, C2H5OH, C2H6, C3H6, C3H6O, C3H8, C4H6, C5H10, C6H12O2, C6H6, C7H8, C8H10, C8H8, CH3OH, CH4, DME, EO, EtAc, H2, i-C4H10, IPA, ISOPARH, MEK, MIBK, MMA, n-C4H10, n-C6H14, n-C7H16, THF, VAc |
NC-1000
Login to view
Features
・Direct reading of the concentration values of combustible gases of 25 gases.
・Easy operation feature of changing the gas name display with 1 switch button.
・Long distance drawing possible with the pump booster function.
・Various combustible gases can be measured by the ppm order with NC-1000.
Category: Gas Detector
Description
Additional information
Target Gas |
C4H10 (Isobutane) ,CH4 (Methane) ,H2 (Hydrogen) |
---|---|
Product Type |
Portable |