Sampling method | Suction type |
Principle of detection | Hot Wire Type Semi-Conductor Method |
Detection range | 10 to 10000 ppm |
Alarm setpoints | Default: 30 ppm (set one of five levels: 10, 30, 150, 500 and 2000 ppm) |
Type of alarm | Gas alarm / Fault alarm |
Display of alarm | Lamp blinking / intermittent buzzer sounding |
Explosion protected construction | Intrinsic safety |
Explosion-proof class | IECEx : Ex ia IIC T4 Ga ATEX : II1G Ex ia IIC T4 Ga |
Ingress proof rating | IP55 |
Approvals | Japan Ex, ATEX, IECEx |
CE marking | EMC / ATEX / RoHS |
Power source | AA alkaline battery 2 pcs. |
Continuous operation | Approx. 13 hours (alkaline batteries, at 20ºC, without alarms or lighting) |
Dimensions | Approx. 43 (W) × 200 (H) × 39 (D) mm (projection portions excluded) |
Weight | Approx. 215 g (without batteries) |
Operating temperature range | -20 to +55 ºC (no sudden changes) |
Operating humidity range | 0 to 95 %RH (Non-condensing) |
SP-220 TYPE L
Login to view
Features
・TYPE L : for LPG
・Strong for impact and dirt, robust and stylish body.
・Quick and reliable detection for small amount of gas leakage.
・The durability of the sensor has been improved with a built- in filter.
・Data logger function equipped (256 data at the maximum can be recorded).
・Safe even in a dark place with the LED light.
Category: Gas Detector
Description
Additional information
Weight | 215 g |
---|---|
Dimensions | 39 × 43 × 200 mm |
Model | |
Target Gas |
AsH3 (Arsine) ,C3H8O (Isopropyl Alcohol) ,CH4 (Methane) ,H2 (Hydrogen) ,NH3 (Ammonia) ,PH3 |
Fixed / Portable |
Portable |
Lead Time |